D (Rh) Typing: Survey Deficiencies and CLIA Citations
Most Rh (D) Typing citations come from five places: quality control (42 CFR 493.1256), calibration verification (42 CFR 493.1255), proficiency testing or accuracy verification, method verification (42 CFR 493.1253) and test reporting, including critical values (42 CFR 493.1291). Keep the records for each area current and you remove most of the risk.
Where Rh (D) Typing citations come from
Survey findings about Rh (D) Typing almost always trace to a short list of 42 CFR 493 standards. This table shows each one and the records a surveyor will usually ask to see.
| Area | Regulation | Records surveyors ask for |
|---|---|---|
| QC | 42 CFR 493.1256 | Daily Rh (D) Typing QC records, Levey-Jennings charts, corrective action log, control lot ranges |
| Proficiency testing | 42 CFR 493.801, Subpart H | Rh (D) Typing PT enrollment, attestation statements, graded reports, investigation of every miss |
| Method verification | 42 CFR 493.1253 | Rh (D) Typing verification study: accuracy, precision, reportable range, reference interval check, director sign-off |
| Test report and critical values | 42 CFR 493.1291 | Critical value list, call log with read-back, report format showing Rh (D) Typing reference intervals |
| Personnel | Subpart M | Training and competency records for everyone who runs Rh (D) Typing |
PT status for Rh (D) Typing
D (Rh) Typing is a regulated analyte (immunohematology, 42 CFR 493.959). CLIA PT acceptance limit: 100% accuracy.
Specimen problems that turn into Rh (D) Typing findings
Preanalytical errors become citations when the lab has no written rule for them, or does not follow its own rule.
- Positive patient identification at collection is the single most important control; use your two-identifier and labeling policy.
- ABO group must be determined with at least anti-A and anti-B reagents and confirmed by testing the serum with known A1 and B red cells (42 CFR 493.1271(a)(2)).
- Weak D testing policy should be written and followed consistently.
If Rh (D) Typing was cited on your survey
- Identify the exact standard cited and the records the surveyor reviewed.
- Look back at patient results that could have been affected and decide whether corrected reports are needed.
- Fix the system, not just the instance, and assign monitoring.
- Write the plan of correction. See the CLIA plan of correction guide.
Related tests
Full guide: D (Rh) Typing testing in the clinical lab: CLIA, PT and QC requirements on soundlabconsult.com, part of the Laboratory Test Compliance Library.
Cited on a CLIA survey?
Sound Lab Consultants helps laboratories read their citations, find root causes and write plans of correction.
Related guides on soundlabconsult.com:
Frequently asked questions
What are the most common Rh (D) Typing survey deficiencies?
Missing or undocumented QC, missed calibration verification, PT or accuracy verification gaps, no method verification study, and undocumented critical value calls for Rh (D) Typing. These are general categories, not statistics.
Which regulation covers Rh (D) Typing quality control?
42 CFR 493.1256 sets the control procedure requirements.
Is Rh (D) Typing on the CLIA PT analyte list?
D (Rh) Typing is a regulated analyte (immunohematology, 42 CFR 493.959). CLIA PT acceptance limit: 100% accuracy.
Sources
- 42 CFR 493.959, Immunohematology
- 42 CFR 493.1256, Control procedures
- 42 CFR 493.1255, Calibration and calibration verification
- 42 CFR 493.1253, Establishment and verification of performance specifications
- 42 CFR 493.1291, Test report
- 42 CFR 493.1236, Evaluation of proficiency testing performance
- CMS CLIA Year 2024 Top 10 Standard- and Condition-Level Deficiencies
- CMS State Operations Manual, Appendix C (Laboratories)